OBD-II · Engine and powertrain (P)
P2047
AdBlue dosing injector circuit/open bank 1 unit 1
What it means
The engine computer sees an open circuit in the AdBlue dosing injector (the valve in the exhaust that sprays AdBlue). On vehicles with SCR, a confirmed unresolved fault may trigger reduced performance or a no-restart countdown; follow the displayed warning and the vehicle handbook.
Symptoms
- AdBlue/emissions warning, possibly with a no-start countdown
- engine warning light
Likely causes, most likely first
| No. | Cause |
|---|---|
| 01 | failed dosing injector coil (heat damage) |
| 02 | melted or corroded connector near the exhaust |
| 03 | broken wiring |
| 04 | engine computer or SCR control unit driver fault (rare) |
What to check, step by step
- 01Inspect the injector connector and wiring near the exhaust for heat damage.
- 02Measure the injector coil resistance and compare with specification.
- 03Check wiring continuity back to the control unit.
- 04Replace the dosing injector if open; use a new gasket and check for crystals in the mounting.